Áù¡¢JY-SPM Start Control Features JY-SPMÆô¶¯¿ØÖÆÌصã

1£®Communicate lubricating oil pump protection in the system fails, DC pumps reliable interaction with the DCS system.

±£ÕϽ»Á÷Èó»¬ÓͱÃÔÚϵͳ³öÏÖ¹ÊÕÏʱ£¬Ö±Á÷Óͱÿɿ¿ÓëDCSϵͳÁª¶¯¡£ 2£®To overcome the traditional start-up mode when starting grid for the DC system or pollution, to avoid a total network of relay protection and other online devices malfunction. ¿Ë·þÁË´«Í³Æô¶¯·½Ê½Æô¶¯Ê±¶ÔÖ±Á÷µçÍøϵͳµÄÓ°Ïì»òÎÛȾ£¬±ÜÃâÔì³É¼Ìµç±£»¤ºÍ¹²Íø¹¤×÷µÄÆäËüÔÚÏß×°ÅZÎó¶¯×÷¡£

3£®Solve the conventional contactor control system easy to burn contact bonding phenomenon. ½â¾ö´«Í³Ê½¿ØÖÆϵͳÖнӴ¥Æ÷´¥Í·ÈÝÒ×ÉÕÕ³½áÏÖÏó¡£

4£®Efficient use of electricity, there is no power loss when starting and heat generated. ÓÐЧÀûÓõçÄÜ£¬Æô¶¯Ê±Ã»ÓеçÄÜËðºÄºÍÈÈÁ¿²úÉú¡£ 5£®Can frequently start, start the non-rush current, smooth start. ¿ÉƵ·±Æô¶¯£¬Æô¶¯ÎÞ³å»÷µçÁ÷£¬Æ½»¬Æô¶¯¡£

6£®Remote or local operation can be arbitrary selection, but also linked the parison low pressure to start DC oil pump.

Ô¶·½»ò¾ÍµØ²Ù×÷¿ÉÈÎÒâÑ¡Ôñ£¬»¹¿ÉÁª¶¯Ä¸¹ÜѹÁ¦µÍÆô¶¯Ö±Á÷Óͱᣠ7£®Touch screen display operating parameters, parameter setting, and fault records. ´¥ÃþÆÁÏÔʾÔËÐвÎÊý¡¢²ÎÊýÉèÅZ¡¢¹ÊÕϼǼ¡£ 8£®Device designed to control the entire import. È«½ø¿Ú¿ØÖÆÆ÷¼þÉè¼Æ

9£®Small size, light weight, good installation, easy to operate.

4

Ìå»ýС¡¢ÖØÁ¿Çá¡¢ºÃ°²×°¡¢ÒײÙ×÷¡£ Æß¡¢Function ¹¦ÄÜ

1£®Man-machine interface: Text information display as a display. ÈË»ú½çÃ棺Îı¾ÏÔʾÆ÷×÷ΪÐÅÏ¢ÏÔʾ¡£

2£®Fault self-diagnosis: JY-SPM Devices running before or at the operation of self-diagnosis of the current ability to work properly.

¹ÊÕÏ×ÔÕï¶Ï£ºJY-SPM×°ÅZÔÚÔËÐÐÇ°»òÔËÐÐÖпÉ×ÔÐÐÕï¶Ïµ±Ç°ÄÜ·ñÕý³£¹¤×÷¡£ 3£®Over-temperature protection: start or run-time, JY-SPM power device internal temperature exceeds 75-80¡æ, the alarm immediately.

¹ýÈȱ£»¤£ºÆô¶¯»òÔËÐÐʱ£¬JY-SPMÄÚ²¿¹¦ÂÊÆ÷¼þζȳ¬¹ý75-80¡æʱ£¬Á¢¿Ì±¨¾¯¡£ 4£®Status Display: Designed in the control cabinet door status indicators and the JY-SPM on Touch Panel displays the current work status is to stop running, start running, fault protection, as well as remote or on-site work status display.

״̬ÏÔʾ£ºÔÚ¿ØÖÆÏäÃÅÉè¼Æ״ָ̬ʾµÆºÍÔÚJY-SPM´¥ÃþÆÁÉÏÏÔʾµ±Ç°¹¤×÷״̬ΪֹͣÔËÐС¢Æô¶¯ÔËÐС¢¹ÊÕϱ£»¤ÒÔ¼°Ô¶·½»ò¾ÍµØ¹¤×÷µÈ״̬ÏÔʾ¡£

5£®Real-time monitoring: Start or run-time, which can effectively monitor the current load the motor armature coil voltage, current, excitation coil current work.

ʵʱ¼à²â£ºÆô¶¯»òÔËÐÐʱ£¬¿ÉÓÐЧ¼àÊÓµ±Ç°¸ºÔصç»úµÄµçÊàÏßȦ¹¤×÷µçѹ¡¢µçÁ÷¡¢Àø´ÅÏßȦ¹¤×÷µçÁ÷¡£

6£®Synchronous Remote Output: Stop, Protection, Operation, operation mode selection, all passive contact output, contact capacity AC250V/5A.

ͬ²½Ò£ÐÅÊä³ö£ºÍ£»ú¡¢±£»¤¡¢ÔËÐС¢ÔËÐÐģʽѡÔñ£¬¾ùΪÎÞÔ´½ÓµãÊä³ö£¬½ÓµãÈÝÁ¿ÎªAC250V/5A¡£

7£®Permissions Password: set the parameters by the permissions of all password-protected to prevent the non-operators can modify.

ȨÏÞ¿ÚÁËùÓÐÉèÅZ²ÎÊýÊÜȨÏÞÃÜÂë±£»¤£¬ÒÔ·À·Ç²Ù×÷ÈËÔ±ËæÒâÐ޸ġ£ 8£®Remote control input: DCS system, turbine, thermal, pressure home boot, stop control, signal contacts are instantaneous. (Short pulse)

Ô¶·½¿ØÖÆÊäÈ룺DCSϵͳ¿ª»ú¡¢Í£»ú¡¢Èȹ¤¿ª»ú¿ØÖÆ¡¢Ä¸¹ÜѹÁ¦¿ª»ú£¬¾ùΪ˲ʱ½ÓµãÐźš££¨¶ÌÂö³å£©

5

9£®Analog Output: Load motor armature coil current values to start running the standard analog output, 4-20mA, can access DCS system.

Ä£ÄâÁ¿Êä³ö£º¸ºÔصç»úµçÊàÏßȦÆô¶¯ÔËÐеçÁ÷ÖµµÄ±ê׼ģÄâÁ¿Êä³ö£¬4-20mA£¬¿É½ÓÈëDCSϵͳ¡£

11£®Communication Interface: RS485 Interface. ͨѶ½Ó¿Ú£ºRS485½Ó¿Ú¡£

°Ë¡¢Product Model Name ²úÆ·ÐͺÅÃüÃû

¾Å¡¢Basic Technical Parameters »ù±¾¼¼Êõ²ÎÊý 1£®Rated Voltage: DC 220V¡À10% ¶î¶¨µçѹ£ºDC 220V¡À 2£®Load Type: Shunt ¸ºÔØÀàÐÍ£º²¢Àø

3£®Load Power: DC220V when powered, 1kW-75kW ¸ºÔع¦ÂÊ£ºDC220V¹©µçʱ£¬1kW -75kW

4£®Cabinet Materials: 2.0mm Thickness Cold-rolled plate ÏäÌå²ÄÁÏ£º2.0mmºñÀäÔþ°å

5£®Size: Height¡ÁWidth¡ÁThickness = 1200mm ¡Á 750mm ¡Á 360mm (Floor type) ÏäÌå³ß´ç£º¸ß¡Á¿í¡Áºñ=1200mm¡Á750mm¡Á360mm£¨ÂäµØʽ£©

Height¡ÁWidth¡ÁThickness = 1000mm ¡Á 750mm ¡Á 360mm (Wall mounted)

¸ß¡Á¿í¡Áºñ=1000mm¡Á750mm¡Á360mm£¨±Ú¹Òʽ£© 6£®Installation Method: Floor type Wall mounted °²×°·½Ê½£ºÂäµØʽ ±Ú¹Òʽ

Ê®¡¢The application of environmental parameters ÊÊÓû·¾³²ÎÊý

6

1£®Ambient Temperature: -25¡æ¡«+60¡æ »·¾³Î¶ȣº-25¡æ- +60¡æ

2£®Environment Humidity: ¡Ü90%RH No condensation »·¾³Êª¶È£º¡Ü90%RHÎÞÄý¶ 3£®Altitude: 3000 Meters and below º£°Î¸ß¶È£º3000Ã×¼°ÒÔÏÂ

4£®Equipment Installation: With the vertical gradient of not more than 5 degrees É豸°²×°£ºÓë´¹Ö±ÃæÇãб¶È²»³¬¹ý5¶È

5£®Install Location: Should be installed in the absence of severe vibration and shock of the place, as well as the lack of electrical components and so are the places of corrosion. °²×°µØµã£ºÓ¦°²×°ÔÚÎÞ¾çÁÒÕ𶯺ͳå»÷µÄµØ·½£¬ÒÔ¼°²»×ãÓëʹµçÆøÔª¼þÊܵ½¸¯Ê´µÄ ³¡Ëù

ʮһ¡¢Overall Dimensions ÍâÐγߴç

Floor Type Profile Schematic Diagram ÂäµØʽÍâÐÎʾÒâͼ

7