直流润滑油泵控制箱说明书(操作说明书)中英文 联系客服

发布时间 : 星期三 文章直流润滑油泵控制箱说明书(操作说明书)中英文更新完毕开始阅读2f37a733c850ad02df80410a

Wall Mounted Outline dimensions 壁挂式式外形示意图

十二、Use and operation 使用与操作

Receive products,check whether the product model is consistent with the required. 收到产品时,先查看是否与所需产品型号是否一致 1.

Installation 安装:

Floor type 落地式

Cabinet at the bottom of the design of fixed holes around the center distance is 690mm, before and after the fixed-hole center distance for 220mm, aperture ?12mm. Users may in accordance with the actual situation at the scene to determine the installation of control cabinet based on the location, design 4-bit fixed-hole.

箱体底部设计固定孔,左右中心距为 690mm, 前后固定孔中心距为220 mm,孔径?为12 mm.用户可根据现场实际情况依据控制箱确定安装位臵,设计4个孔位固定。

8

690mmΦ12×4220mm360 mmΦ60×5

Wall mounted 壁挂式

The back design of the fixed-hole box (with installation accessories), left center distance is 590mm, the upper and lower fixed-hole center distance of 1081 mm, diameter ?12mm.Users can control cabinet based on the actual situation on-site installation to determine the location, design four holes fixed.

箱体背部设计固定孔(带安装附件),左右中心距为 590mm, 上下固定孔中心距为1081mm,孔径为?12 mm.用户可根据现场实际情况依据控制箱确定安装位臵,设计4 个孔位固定。

590mmΦ12×4877mm1081mm 2.Wiring 接线:

JY-ZK Control cabinet for the next round into the form of design, reserved cabinet at the bottom 5 of a diameter of 60 mm threading hole, wiring diagram, see the attached map:

JY-ZK控制箱为下进出线形式设计,箱体底部预留5个直径为60 mm的穿线孔,接线图见附图:

Note: X1 X2 for JY-SPM devices into the DC power line (Users do not have to consider).

9

X3 X4 for DC motor armature coil terminal, X3 for the positive, X4 for the negative.

X5 X6 For DC motor excitation coil terminal, X5 for the positive, X6 for negative. 注意: X1 X2 为JY-SPM装臵的直流电源进线(用户不用考虑) X3 X4 为直流电机电枢线圈接线端,X3为正极,X4为负极 X5 X6 为直流电机励磁线圈接线端,X5为正极,X6为负极

Designed at the scene such as the laying of cables for the three, it must be DC motor armature coil positive and connected excitation coil positive, with a wire to connect the X3 SPM device, the other two wires are DC motor armature coil negative to the X4 SPM devices, DC motor excitation coil negative to X6 SPM devices, X5 vacant will not receive any wires. Avoid the two-coil DC motor applications at the negative JY-SPM device and then will never be allowed to use in order to prevent burn SPM devices or DC motor.

如现场设计敷设电缆为三根时,必须将直流电动机的电枢线圈正极与励磁线圈正极相连接,用一根导线将其与SPM装臵的X3连接,另外两根导线分别为直流电动机电枢线圈的负极到SPM装臵的X4,直流电动机励磁线圈的负极到SPM装臵的X6,X5悬空不接任何导线。切忌直流电机两个线圈的负极在应用JY-SPM装臵时绝对不允许并接使用,以防烧坏SPM装臵或直流电动机。

+L -L for the DC power into the line terminal, +L for the positive,-L for the negative.

Control terminal can be the actual situation based on user selection wiring, no wiring device ports will not affect the normal use! Please follow the correct wiring drawings, otherwise, would result in equipment damage!!

+L -L为直流电源进线接线端,+L为正极,-L为负极

控制接线端可根据用户实际情况选择接线,没有接线的端口不会影响装臵的正常使用!请按照图纸正确接线,否则会导致设备损坏!!

十三、Operation 操作

1. Conventional Operation 常规操作

Then after all the wiring, refer to wiring diagram on both sides of double-check with a

10

multimeter measuring the availability of supply-side short circuit, the accuracy after the first operation of choice under the change-over switch to \the \for the normal power supply connected, the door to \running\light is lit, the power supply voltage multimeter measured correctly, the and then choose to switch to run under \and press the start button, the door to \running\indicator goes out, \start running \armature voltage and current from small to large automatic adjustment of output, up to rated voltage, and motor speed from slow to fast until they reach their rated speed, start the process of running the end of the direct normal. At this point if the detected fault and fault protection is set, control box may stop working, fail-safe indicator light was lit. If the control box in normal operation by pressing the \control box may stop working, \

所有接线接完后,参考接线图仔细检查两边,用万用表测量电源端有无短路,准确无误后,先将运行选择转换开关臵于“停止” 位,分别按下“启动”“停止”“急停”三个按钮,判断是否灵活,(按钮均为不带自锁型),检查为正常后,接通供电电源,箱门上“停止运行”指示灯点亮,用万用表测供电电源电压正确后,再将运行选择转换开关臵于“就地”位,按下启动按钮,箱门上“停止运行”指示灯熄灭, “启动运行”指示灯点亮,这时直流电机励磁电压一次输出额定电源,直流电机电枢电压和电流从小到大自动调节输出,直至额定电压,同时电机转速由慢到快,直至达到额定转速,启动过程结束直接转入正常运行。此时若检测到故障且故障保护被设臵,控制箱均可停止工作,故障保护指示灯被点亮。若在控制箱正常运行时按下“停止”或“急停”或运行选择转换开关臵于“停止”位,控制箱均可停止工作,“停止运行”指示灯点亮。

If run after the power selection switch at \and press \operable external control (Remote Signal), at this time if the boot DCS signal, thermal boot signal, the mother tube pressure boot arbitrary signals the arrival of a signal,

control cabinet can be activated to operate on door to \Running\indicator goes out,

11